FIRE ALARM: AN ESSENTIAL ELEMENT FOR THE PROTECTION OF YOUR LOVED ONES AND YOUR PROPERTY

Be alerted in the event of a fire so that you can take appropriate action and evacuate as quickly as possible.

SERVICE

Our team of qualified technicians are trained to ensure your fire alarm systems work properly. Our 24/7 emergency services ensure a quick and efficient response, regardless of your situation.

CENTRAL ALARM

In order to secure your installations, Safety First Fire Prevention also offers a central monitoring service. Whether it is for a new installation, for the modernization of your installation or that you wish to centralize your services in order to facilitate their management, you can count on us to watch over all your buildings.

DID YOU KNOW?

The inspection of fire alarm system is governed by the can/ULC-S536 standard. This standard mentions that an “annual inspection must be performed within 12 months of the date of the last inspection” (section 4.2). It also stipulates in appendix A that “any person who performs the annual inspection and testing of a fire alarm system must be familiar with this standard and have received adequate formal training or have sufficient experience acceptable to the authority having jurisdiction.

DID YOU KNOW?

The inspection of fire alarm system is governed by the can/ULC-S536 standard. This standard mentions that an “annual inspection must be performed within 12 months of the date of the last inspection” (section 4.2). It also stipulates in appendix A that “any person who performs the annual inspection and testing of a fire alarm system must be familiar with this standard and have received adequate formal training or have sufficient experience acceptable to the authority having jurisdiction.

EMERGENCY LIGHTING

EMERGENCY LIGHTING SYSTEMS

Its function is to provide a source of lighting when the power goes out. Every model therefore needs some sort of battery or generator system that can provide power to the lights during a blackout.

MAINTAINED LIGHTING

Maintained emergency lighting are built to be illuminated continuously all the time, as well as through a power cut. While they run normally taking power from the mains supply, when the emergency mode is triggered, they take power from the back up battery.

NON-MAINTAINED

Non-maintained emergency lighting only come on when the electrical power supply fails, they are produced solely for emergency use. It is designed to make sure all emergency exit routes are lit, but will not be active as your normal day-to-day lighting system.

LED EMERGENCY LIGHTING

LED lighting is a highly energy efficient option for emergency or general lighting. However when it is running off of back-up power, it is important that the batteries last. LED lights can be used to reduce power consumption as well as to reduce the trickle charge for the topping-up of the back-up battery.

PLANNED MAINTENANCE

Ensuring the lighting tubes inside of your emergency system are working is one thing but it is nothing without a working back-up battery. The back-up batteries will be capable of providing anywhere from 30 minutes to 3 hours of emergency lighting depending on the design occupancy requirements.